

无数据
Scan QR Code
1.Department of Clinical Laboratory, Guangzhou Institute of Respiratory Health, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, National Clinical Research Center for Respiratory Disease, Guangzhou Laboratory, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510140, China
2.KingMed School of Laboratory Medicine, Guangzhou Medical University, Guangzhou 511495, China
3.College of Medical Technology, Guangdong Medical University, Dongguan 523121, China
4.Second Clinical Medical School, Southern Medical University, Guangzhou 510515, China
Received:12 June 2023,
Revised:08 November 2023,
Published Online:18 January 2025,
Published:25 February 2025
刘铭涛,刘俐,陈珈晞等.床旁即时检测分析仪在血清生化十三项指标与全血凝血五项指标的应用:评估呼吸与危重症疾病的理想工具[J].浙江大学学报(英文版)(B辑:生物医学和生物技术),2025,26(02):158-171.
Mingtao LIU, Li LIU, Jiaxi CHEN, et al. Thirteen serum biochemical indexes and five whole blood coagulation indices in a point-of-care testing analyzer: ideal protocol for evaluating pulmonary and critical care medicine[J]. Journal of zhejiang university-science b (biomedicine & biotechnology), 2025, 26(2): 158-171.
刘铭涛,刘俐,陈珈晞等.床旁即时检测分析仪在血清生化十三项指标与全血凝血五项指标的应用:评估呼吸与危重症疾病的理想工具[J].浙江大学学报(英文版)(B辑:生物医学和生物技术),2025,26(02):158-171. DOI: 10.1631/jzus.B2300433.
Mingtao LIU, Li LIU, Jiaxi CHEN, et al. Thirteen serum biochemical indexes and five whole blood coagulation indices in a point-of-care testing analyzer: ideal protocol for evaluating pulmonary and critical care medicine[J]. Journal of zhejiang university-science b (biomedicine & biotechnology), 2025, 26(2): 158-171. DOI: 10.1631/jzus.B2300433.
生化和凝血指标的准确及时检测对呼吸及危重症患者至关重要。传统实验室检测虽可靠,但往往较为滞后。床边即时检测(POCT)已成为一种潜在的替代方法,但仍待严格验证。使用Beckman Coulter AU5821和PUSHKANG POCT生化分析仪以及Stago STAR MAX和PUSHKANG POCT凝血分析仪分别对广州医科大学附属第一医院的226份血清和350份全血样本进行包括白蛋白等十三项生化指标和凝血酶原时间等五项凝血指标进行比对检测。Bland-Altman图(MS100: 0.8206‒0.9995; MC100: 0.8318‒0.9911)一致性较好。Spearman相关分析显示,传统仪器和PUSHKANG POCT分析仪之间存在显著的线性相关性,且相关系数稳健(MS100: 0.713‒0.949; MC100: 0.593‒0.950)。PUSHKANG POCT作为一种可靠的血清、全血生化和凝血快速诊断工具,具有稳定的临床评价功能,可为呼吸与危重症临床医师在患者紧急病况时提供及时预示。
The accurate and timely detection of biochemical coagulation indicators is pivotal in pulmonary and critical care medicine. Despite their reliability
traditional laboratories often lag in terms of rapid diagnosis. Point-of-care testing (POCT) has emerged as a promising alternative
which is awaiting rigorous validation. We assessed 226 samples from patients at the First Affiliated Hospital of Guangzhou Medical University using a Beckman Coulter AU5821 and a PUSHKANG POCT Biochemistry Analyzer MS100. Furthermore
350 samples were evaluated with a Stago coagulation analyzer STAR MAX and a PUSHKANG POCT Coagulation Analyzer MC100. Metrics included thirteen biochemical indexes
such as albumin
and five coagulation indices
such as prothrombin time. Comparisons were drawn against the PUSHKANG POCT analyzer. Bland-Altman plots (MS100: 0.8206‒0.9995; MC100: 0.8318‒0.9911) evinced significant consistency between methodologies. Spearman correlation pinpointed a potent linear association between conventional devices and the PUSHKANG POCT analyzer
further underscored by a robust correlation coefficient (MS100: 0.713‒0.949; MC100: 0.593‒0.950). The PUSHKANG POCT was validated as a dependable tool for serum and whole blood biochemical and coagulation diagnostics. This emphasizes its prospective clinical efficacy
offering clinicians a swift diagnostic tool and heralding a new era of enhanced patient care outcomes.
Athale UH , Chan AKC , 2003 . Thrombosis in children with acute lymphoblastic leukemia: Part II . Pathogenesis of thrombosis in children with acute lymphoblastic leukemia : effects of the disease and therapy. Thromb Res , 111 ( 4-5 ): 199 - 212 . https://doi.org/10.1016/j.thromres.2003.10.007 https://doi.org/10.1016/j.thromres.2003.10.007
Briggs C , Kimber S , Green L , 2012 . Where are we at with point‐of‐care testing in haematology?Br J Haematol , 158 ( 6 ): 679 - 690 . https://doi.org/10.1111/j.1365-2141.2012.09207.x https://doi.org/10.1111/j.1365-2141.2012.09207.x
Chase JG , Preiser JC , Dickson JL , et al. , 2018 . Next-generation, personalised, model-based critical care medicine : a state-of-the art review of in silico virtual patient models, methods, and cohorts, and how to validation them. Biomed Eng Online , 17 : 24 . https://doi.org/10.1186/s12938-018-0455-y https://doi.org/10.1186/s12938-018-0455-y
China Food and Drug Administration , 2014 . Notice of the State Food and Drug Administration in China on Issuing Technical Guidelines for Clinical Trials of In Vitro Diagnostic Reagents . https://www.nmpa.gov.cn/directory/web/nmpa//xxgk/ggtg/ylqxggtg/ylqxqtggtg/20140911120001840.html https://www.nmpa.gov.cn/directory/web/nmpa//xxgk/ggtg/ylqxggtg/ylqxqtggtg/20140911120001840.html
Clinical and Laboratory Standards Institute , 2012 . Verification of Comparability of Patient Results Within One Health Care System; Approved Guideline . CLSI Document C54-A , Clinical and Laboratory Standards Institute , Wayne.
Clinical and Laboratory Standards Institute , 2013 . Measurement Procedure Comparison and Bias Estimation Using Patient Samples; Approved Guideline . Third Edition . CLSI Document EP09 - A3 , Clinical and Laboratory Standards Institute, Wayne.
Cui P , Wang SC , 2019 . Application of microfluidic chip technology in pharmaceutical analysis: a review . J Pharm Anal , 9 ( 4 ): 238 - 247 . https://doi.org/10.1016/j.jpha.2018.12.001 https://doi.org/10.1016/j.jpha.2018.12.001
Ebner M , Birschmann I , Peter A , et al. , 2017 . Point-of-care testing for emergency assessment of coagulation in patients treated with direct oral anticoagulants . Crit Care , 21 : 32 . https://doi.org/10.1186/s13054-017-1619-z https://doi.org/10.1186/s13054-017-1619-z
Florkowski C , Don-Wauchope A , Gimenez N , et al. , 2017 . Point-of-care testing (POCT) and evidence-based laboratory medicine (EBLM)‒does it leverage any advantage in clinical decision making? Crit Rev Clin Lab Sci , 54 ( 7-8 ): 471 - 494 . https://doi.org/10.1080/10408363.2017.1399336 https://doi.org/10.1080/10408363.2017.1399336
Fragoso CAV , 2017 . Epidemiology of lung disease in older persons . Clin Geriatr Med , 33 ( 4 ): 491 - 501 . https://doi.org/10.1016/j.cger.2017.06.003 https://doi.org/10.1016/j.cger.2017.06.003
Gervais L , de Rooij N , Delamarche E , 2011 . Microfluidic chips for point‐of‐care immunodiagnostics . Adv Mater , 23 ( 24 ): H151 - H176 . https://doi.org/10.1002/adma.201100464 https://doi.org/10.1002/adma.201100464
Greenhalgh T , Knight M , A'Court C , et al. , 2020 . Management of post-acute COVID-19 in primary care . BMJ , 370 : m3026 . https://doi.org/10.1136/bmj.m3026 https://doi.org/10.1136/bmj.m3026
Herrmann J , Notz Q , Schlesinger T , et al. , 2021 . Point of care diagnostic of hypercoagulability and platelet function in COVID-19 induced acute respiratory distress syndrome: a retrospective observational study . Thromb J , 19 : 39 . https://doi.org/10.1186/s12959-021-00293-8 https://doi.org/10.1186/s12959-021-00293-8
Ichkawa Y , Wada H , Ezaki M , et al. , 2020 . Elevated d -dimer levels predict a poor outcome in critically ill patients . Clin Appl Thromb Hemost , 26 : 1076029620973084 . https://doi.org/10.1177/1076029620973084 https://doi.org/10.1177/1076029620973084
Lin J , Yan H , Chen HC , et al. , 2021 . COVID‐19 and coagulation dysfunction in adults: a systematic review and meta‐analysis . J Med Virol , 93 ( 2 ): 934 - 944 . https://doi.org/10.1002/jmv.26346 https://doi.org/10.1002/jmv.26346
Liu MT , Cheng ZJ , Xue MS , et al. , 2023a . The application of metabolomics toward idiopathic pulmonary fibrosis and potential metabolomic value of diverse samples in interstitial lung diseases . Precis Med Sci , 12 ( 3 ): 134 - 143 . https://doi.org/10.1002/prm2.12106 https://doi.org/10.1002/prm2.12106
Liu MT , Lyu J , Zheng XH , et al. , 2023b . Evolution of the newest diagnostic methods for COVID-19: a Chinese perspective . J Zhejiang Univ-Sci B (Biomed & Biotechnol) , 24 ( 6 ): 463 - 484 . https://doi.org/10.1631/jzus.B2200625 https://doi.org/10.1631/jzus.B2200625
Liu MT , Liang ZM , Cheng ZK , et al. , 2023c . SARS-CoV-2 neutralising antibody therapies: recent advances and future challenges . Rev Med Virol , 33 ( 5 ): e2464 . https://doi.org/10.1002/RMV.2464 https://doi.org/10.1002/RMV.2464
Luppa PB , Müller C , Schlichtiger A , et al. , 2011 . Point-of-care testing (POCT): current techniques and future perspectives . TrAC Trends Anal Chem , 30 ( 6 ): 887 - 898 . https://doi.org/10.1016/j.trac.2011.01.019 https://doi.org/10.1016/j.trac.2011.01.019
Luppa PB , Bietenbeck A , Beaudoin C , et al. , 2016 . Clinically relevant analytical techniques, organizational concepts for application and future perspectives of point-of-care testing . Biotechnol Adv , 34 ( 3 ): 139 - 160 . https://doi.org/10.1016/j.biotechadv.2016.01.003 https://doi.org/10.1016/j.biotechadv.2016.01.003
Mansour SA , Mossa ATH , 2010 . Oxidative damage, biochemical and histopathological alterations in rats exposed to chlorpyrifos and the antioxidant role of zinc . Pestic Biochem Physiol , 96 ( 1 ): 14 - 23 . https://doi.org/10.1016/j.pestbp.2009.08.008 https://doi.org/10.1016/j.pestbp.2009.08.008
Parikh CR , 2009 . A point-of-care device for acute kidney injury: a fantastic , futuristic, or frivolous ‘measure’? Kidney Int, 76 ( 1 ): 8 - 10 . https://doi.org/10.1038/ki.2009.125 https://doi.org/10.1038/ki.2009.125
Parshall MB , Schwartzstein RM , Adams L , et al. , 2012 . An official american thoracic society statement: update on the mechanisms, assessment, and management of dyspnea . Am J Respir Crit Care Med , 185 ( 4 ): 435 - 452 . https://doi.org/10.1164/rccm.201111-2042ST https://doi.org/10.1164/rccm.201111-2042ST
Sher M , Zhuang R , Demirci U , et al. , 2017 . Paper-based analytical devices for clinical diagnosis: recent advances in the fabrication techniques and sensing mechanisms . Expert Rev Mol Diagn , 17 ( 4 ): 351 - 366 . https://doi.org/10.1080/14737159.2017.1285228 https://doi.org/10.1080/14737159.2017.1285228
Soler M , Estevez MC , Cardenosa-Rubio M , et al. , 2020 . How nanophotonic label-free biosensors can contribute to rapid and massive diagnostics of respiratory virus infections: COVID-19 case . ACS Sens , 5 ( 9 ): 2663 - 2678 . https://doi.org/10.1021/acssensors.0c01180 https://doi.org/10.1021/acssensors.0c01180
Song JC , Wang G , Zhang W , et al. , 2020 . Chinese expert consensus on diagnosis and treatment of coagulation dysfunction in COVID-19 . Military Med Res , 7 : 19 . https://doi.org/10.1186/s40779-020-00247-7 https://doi.org/10.1186/s40779-020-00247-7
St-Louis P , 2000 . Status of point-of-care testing: promise, realities, and possibilities . Clin Biochem , 33 ( 6 ): 427 - 440 . https://doi.org/10.1016/S0009-9120(00)00138-7 https://doi.org/10.1016/S0009-9120(00)00138-7
Stoot LJ , Cairns NA , Cull F , et al. , 2014 . Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review . Conserv Physiol , 2 : cou011 . https://doi.org/10.1093/conphys/cou011 https://doi.org/10.1093/conphys/cou011
Taneja R , Batra P , 2021 . Biomarkers as point of care tests (POCT) in neonatal sepsis: a state of science review . J Neonat-Perinat Med , 14 ( 3 ): 331 - 338 . https://doi.org/10.3233/NPM-200581 https://doi.org/10.3233/NPM-200581
Torres N , Torre-Villalvazo I , Tovar AR , 2006 . Regulation of lipid metabolism by soy protein and its implication in diseases mediated by lipid disorders . J Nutr Biochem , 17 ( 6 ): 365 - 373 . https://doi.org/10.1016/j.jnutbio.2005.11.005 https://doi.org/10.1016/j.jnutbio.2005.11.005
Vesper HW , Myers GL , Miller WG , 2016 . Current practices and challenges in the standardization and harmonization of clinical laboratory tests . Am J Clin Nutr , 104 ( S3 ): 907S - 912S . https://doi.org/10.3945/ajcn.115.110387 https://doi.org/10.3945/ajcn.115.110387
Volpicelli G , Elbarbary M , Blaivas M , et al. , 2012 . International evidence-based recommendations for point-of-care lung ultrasound . Intens Care Med , 38 ( 4 ): 577 - 591 . https://doi.org/10.1007/s00134-012-2513-4 https://doi.org/10.1007/s00134-012-2513-4
Xiao M , Tian F , Liu X , et al. , 2022 . Virus detection: from state‐of‐the‐art laboratories to smartphone‐based point‐of‐care testing . Adv Sci , 9 ( 17 ): 2105904 . https://doi.org/10.1002/advs.202105904 https://doi.org/10.1002/advs.202105904
Xue MS , Zhang T , Cheng ZJ , et al. , 2022 . Effect of a functional phospholipid metabolome-protein association pathway on the mechanism of COVID-19 disease progression . Int J Biol Sci , 18 ( 12 ): 4618 - 4628 . https://doi.org/10.7150/ijbs.72450 https://doi.org/10.7150/ijbs.72450
Zaczek-Moczydlowska MA , Beizaei A , Dillon M , et al. , 2021 . Current state-of-the-art diagnostics for norovirus detection: model approaches for point-of-care analysis . Trends Food Sci Technol , 114 : 684 - 695 . https://doi.org/10.1016/j.tifs.2021.06.027 https://doi.org/10.1016/j.tifs.2021.06.027
Zhang YT , Zhou ND , 2022 . Electrochemical biosensors based on micro‐fabricated devices for point‐of‐care testing: a review . Electroanalysis , 34 ( 2 ): 168 - 183 . https://doi.org/10.1002/elan.202100281 https://doi.org/10.1002/elan.202100281
Zhu HL , Zhang HQ , Ni S , et al. , 2020 . The vision of point-of-care PCR tests for the COVID-19 pandemic and beyond . TrAC Trends Anal Chem , 130 : 115984 . https://doi.org/10.1016/j.trac.2020.115984 https://doi.org/10.1016/j.trac.2020.115984
Zhu HQ , Huang ZF , Huang HM , et al. , 2022 . Evaluation of a point-of-care testing analyzer for measuring peripheral blood leukocytes . J Vis Exp , ( 181): e 63364. https://doi.org/10.3791/63364 https://doi.org/10.3791/63364
0
Views
27
Downloads
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621